Model:PAVA8500

● With one-key alarm and two editable alarm voices; with EMC MIC for on-site guidance in emergencies;
● Built-in EVAC voice message and Chimes management, real-time monitoring;
● Built-in 500W digital power amplifier, and can be connected to a standby amplifier simultaneously, backup automatically;
● 8 zones with A & B circuit output, independent switch and volume control with master volume and treble and bass adjustment for each zone; each zone can output 500W, the total power of 8 zones ≤ 500W;
● 6 external inputs, including 2 differential inputs, 4 non-parallel inputs for background music playback; 1-channel output to connect extender or backup records;
● Support built-in audio playback (mp3, wav);
● Support extended zones for extended equipment, supporting up to 160 zones;

Send Inquiry    PDF Download

Product Description

    Welcome to use DSPPA public address system. For the better use of Dante Integrated Evacuation Voice Alarm Amplifier 500W, please read this instruction carefully prior to use

     With one-key alarm and two editable alarm voices; with EMC MIC for on-site guidance in emergencies;

     Built-in EVAC voice message and Chimes management, real-time monitoring;

     Built-in 500W digital power amplifier, and can be connected to a standby amplifier simultaneously, backup automatically;

     8 zones with A & B circuit output, independent switch and volume control with master volume and treble and bass adjustment for each zone; each zone can output 500W, the total power of 8 zones ≤ 500W;

     6 external inputs, including 2 differential inputs, 4 non-parallel inputs for background music playback; 1-channel output to connect extender or backup records;

     Support built-in audio playback (mp3, wav);

     Support extended zones for extended equipment, supporting up to 160 zones;

     Support automatic playback and timing function, fixed time and area playback, and unattended function;

     8 trigger inputs (dry contacts and electrical level optional); 8 dry contacts trigger outputs, 8 24V override outputs;

     Support computer remote detection and control, audio priority setting, operation record view and impedance testing parameters setting;

     Support speaker line detection (grounding, open circuit, short circuit), and system detection (extended equipment, off-line MIC);

     Support AC power supply and DC 24V power supply, can automatically identify and switch, and detect AC, DC power connection and warn; AC power supply is usually the main power supply;

     Dial-up code setting, system equipment general detection / trigger mode configuration / host IP address selection / host IP address reset option / speaker loop calibration modeling;

     Support system failure, emergency output, emergency reset input;

     Equipment working status display: work/ fault /normal;

     External SD card interface, which can expand 8G storage space; external audio source, recording, log, built-in EVAC voice, etc.;

     With monitoring function, built-in recording function, built-in timing programming function, which can regularly program dry contacts to control power sequencer switch;

     Can output dual audio simultaneously to ensure background playback is not affected by emergency or business broadcast.

    Model

    PAVA8500

    PAVA8500E

    Rated output power

    ≥500W(100V)

    Input sensitivity

    Emergency mic

    5mV 600Ω

     

     

     

     

     

     

     

     

    Line

    1000mV 10kΩ

    Harmonic distortion

    Emergency mic

    <1% 1kHz

     

    Line

    <1% 1kHz

    Freq. response

    Emergency mic

    80Hz-15kHz(±3dB)

     

    Line

    50Hz-18kHz(±3dB)

    Signal to noise ratio

    Emergency mic

    >75dB(A weighting)

     

    Line

    >80dB(A weighting)

    Line output

    Output voltage

    1000mV

     

    Frequency range

    80Hz-15kHz(±3dB)

     

    Harmonic distortion

    <1% 1kHz

    System connection control contact output/input

    System fault relay output

    Short circuit, no voltage

     

    Emergency mode relay output

    Short circuit, no voltage

     

    Fire reset input

    Short circuit, t≥0.5S, no voltage

     

    8 channel dry contact output

    Short circuit, no voltage

     

    8 dry contact input

    Short circuit mode

    Short circuit input, no voltage

     

     

    Level mode

    3.3V~24V

    Voice message

    Data format

    WAV

     

    Storage form

    SD card

     

    Storage time

    >10 years

    Working power

    AC

    AC 220V/50Hz

     

    DC

    DC 24V/30A

    Package size (L*W*H)

    550×510×215mm

    Machine size (L*W*H)

    483×420×132mm

    G.W.

    14kg

    13.3kg

    N.W.

    12.05kg

    11.75kg